Steam Turbine Oil Purifier

Steam Turbine Oil Purifier

The TY-A automatic steam turbine oil purifier runs a PLC-controlled vacuum dehydration and 1µm absolute filtration process to remove water, gas and fine particles from turbine lubricants, delivering residual moisture ≤50 ppm and gas content ≤0.1% without constant operator attendance. It can be used for offline batch treatment or connected for inline oil conditioning while turbine generators remain in service.
Send Inquiry
Description
Technical Parameters

Chongqing TOP Oil Purifier Co., Ltd. is one of the most reliable manufacturers and suppliers of steam turbine oil purifier in China, also supports customized service. Please feel free to buy advanced steam turbine oil purifier made in China here from our factory.

 

Description

 

The TY-A Steam Turbine Oil Purifier runs a PLC-controlled vacuum dehydration and 1µm absolute filtration process to remove water, gas and fine particles from turbine lubricants, delivering residual moisture ≤50 ppm and gas content ≤0.1% without constant operator attendance. It can be used for offline batch treatment or connected for inline oil conditioning while turbine generators remain in service.

 

Technical Parameters

Item

Unit

TY-A

-10

TY-A

-20

TY-A

-30

TY-A

-50

TY-A

-100

TY-A

-150

TY-A

-200

TY-A

-250

TY-A

-300

Flow Rate

L/min

600

1200

1800

3000

6000

9000

12000

15000

18000

Flow Rate

L/H

600

1200

1800

3000

6000

9000

12000

15000

18000

Working Vacuum

Mpa

-0.06 ~- 0.098

Working Pressure

Mpa

≤0.3

Temperature Range

℃

0~100

Working Oil Temperature

℃

45~65

Power Supply

 

380V/50HZ/3Ph 5 wire (Customizable)

Continuous Working Time

H

≥150

Working Noise

dB(A)

≤65

≤68

≤68

≤70

≤70

≤75

≤75

≤78

≤80

Electric Heating Power

kW

15

18

24

36

60

72

120

150

180

Total Electric Power

kW

17

20

26

39

65

79

128

180

192

Inlet/Outlet

mm

Ф25

Ф25

Ф25

Ф32

Ф42

Ф45

Ф50

Ф60

Ф63

Weight

kg

350

400

450

500

900

1300

1500

1800

2000

Size

L

mm

1350

1400

1450

1500

1700

1800

2000

2100

2400

W

mm

950

1000

1050

1100

1150

1250

1400

1450

1550

H

mm

1650

1700

1750

1800

1800

2000

2200

2300

2400

Index After Filtration

Moisture Content

PPM

≤50

Gas Content

%

0.1

Impurity Size

μm

≤1 (Customizable)

 

Features

 

  • Aged transformer oil typically carries dissolved water, acids and oxidation sludge that pull down the breakdown voltage and push the dissipation factor beyond acceptable limits. Regeneration columns packed with activated alumina strip out these acidic compounds and oxidation by‑products, restoring dielectric strength and bringing the oil back within serviceable values.
  • Deep vacuum dehydration reduces dissolved moisture to 10 ppm or below, which raises the breakdown voltage enough for reliable insulation at transmission and distribution voltages.
  • An integrated degassing stage removes dissolved air and other gases to 0.1% or lower, preventing gas bubbles from forming under high electrical stress the kind that lead to partial discharge and eventual insulation failure.
  • Multi-stage fine filtration traps particulate matter down to 1 µm absolute, keeping the oil clean enough for power transformers, instrument transformers and circuit breakers.
  • A PLC-based control system manages the full regeneration cycle without operator attendance and logs process data for maintenance planning and compliance records.

 

FAQ

 

Q: Can it regenerate oil with very high acid value?

A: The regeneration filter can reduce acid value to a certain extent. If oil is severely oxidized with excessive acid value and plenty of asphalt‑like sediments, physical purification alone cannot restore oil completely. It is advised to replace part of new oil.

Q: What ambient conditions are required for operation?

A: Working environment temperature: 5‑45℃; avoid heavy dust, rain and corrosive gas. Indoor installation is preferred; outdoor usage needs rain‑proof shelter.

Q: Troubleshooting: Low vacuum degree, how to check?

A: 1. Check all pipeline joints and door covers for air leakage.
2. Inspect vacuum pump oil quality, replace if deteriorated.
3. Check whether inlet oil flow is too large.
4. Confirm sealing rubber rings are intact.

 

 

Hot Tags: steam turbine oil purifier, China steam turbine oil purifier manufacturers, factory, Steam Turbine Oil Purifier, turbine oil purifier, Turbine Oil Cleaning, Turbine Oil Treatment Machine, Turbine Oil Regeneration Unit, turbine oil filter machine